Fitting a tri-fuel conversion kit from GeneratorGuru.com lets you run your generator on Gasoline, Natural Gas (NG), Propane & Butane (LPG) giving you more fuel options.

Also... Running a portable generator on liquid petroleum gases (LPG) or natural gas (NG) instead of gas offers significant advantages: cleaner combustion, longer engine life, easier storage, and no fuel degradation issues. Whether you're in the UK, USA, Canada, Europe, Australia, Africa or anywhere else in the world, converting your generator to multi-fuel operation is a practical upgrade that can save you money and hassle in the long run.

At Generator Guru, we advise over 100,000 customers a year on generator maintenance, repairs, and conversions. Our team of experienced Generator Engineers has developed comprehensive guides to help you make informed decisions about fuel conversion. Here's what you need to know.

Why Convert to LPG or Natural Gas?

Cleaner Operation: LPG and NG burn significantly cleaner than petrol, producing fewer carbon deposits in your engine. This means less maintenance, cleaner spark plugs, and longer engine life.

Fuel Storage: Gasoline degrades over time and can gum up carburettors if left sitting. LPG and NG don't have this problem — your fuel is always fresh and ready to use.

Cost Savings: In many regions, LPG and NG are cheaper per hour of runtime than petrol. If you use your generator regularly, the savings add up quickly.

Versatility: A tri-fuel generator (gas, LPG, and NG) gives you ultimate flexibility. If one fuel source is unavailable during an emergency, you can switch to another.

Understanding Conversion Kits

Converting your generator requires a dedicated LPG/NG conversion kit designed for your specific engine model. These kits typically include:

  • Gas regulator (to control fuel pressure)
  • Gas mixer assembly (to blend air and gas)
  • Mounting hardware and gaskets

CRITICAL SAFETY WARNING: Converting a generator to run on LPG or NG involves working with pressurised flammable gases. This work should only be performed by competent, experienced individuals who understand gas safety regulations. Ensure you work in a well-ventilated area away from ignition sources. LPG and NG are heavier than air and can accumulate in low areas, creating explosion hazards. Never attempt this conversion if you are not confident in your abilities — consult a qualified engineer or gas safety professional. Improper installation can result in fires, explosions, carbon monoxide poisoning, or death.

The Conversion Process

1. Select the Correct Kit: Parts are NOT interchangeable between different generator brands and models. Visit generatorguru.com and select your specific generator brand and model to find the correct conversion kit for your machine.

2. Install the Kit: The kit replaces or supplements your existing carburettor, allowing gas to be drawn into the engine. Follow the manufacturer's instructions carefully, ensuring all gaskets are properly seated and all mounting bolts are torqued to specification.

3. Connect the Tank Regulator (if needed in your area): The regulator reduces the tank pressure to the correct operating pressure for your engine. 

4. Test for Leaks: Before starting your generator, use soapy water to check every connection for leaks. Bubbles indicate escaping gas. Tighten connections and retest until no leaks are present.

Important Considerations

Power Output: LPG and NG typically produce 10-15% less power than petrol due to lower energy density. If your generator is already running near its maximum capacity, factor this reduction into your planning.

Oil Changes: Continue using the same mineral oil for all servicing. Do NOT use synthetic oil. LPG/NG operation actually keeps your oil cleaner longer, but still follow the manufacturer's recommended service intervals.

Valve Adjustments: Gas operation can affect valve clearances over time. Check your valve clearances regularly — specifications are published on the valve product listings for your specific model at generatorguru.com. See this video for proceedures and look up your "Valves" as we have published the recommended settings in the description under the Brand and Model on our Parts System.

Legal Requirements: Some regions require gas work to be certified by licensed professionals. Check your local regulations before proceeding.

Free Repair Guides and Support

When you select your generator brand and model at generatorguru.com, you'll find FREE Interactive Repair Guides built right into the model page — these guides are written specifically for your exact generator and include step-by-step instructions for common repairs and modifications.

Our Generator Engineers provide completely free repair support — we never charge for advice. If you need help identifying the right conversion kit, troubleshooting installation issues, or adjusting your mixture settings, contact us at generatorguru.com/need-help.

Ready to Convert?

Converting your generator to run on LPG or natural gas is an investment in flexibility, reliability, and long-term savings. With warehouses in the UK, USA, Canada, EU, Australia, Africa and Generator Guru ships worldwide to support customers on every continent.

Visit generatorguru.com today, select your generator brand and model, and explore the conversion kits and parts available for your machine. Join the thousands of customers who've already made the switch to cleaner, more convenient generator operation.

#RightToRepair — We empower you to maintain and upgrade your own equipment with the parts, guides, and free engineer support you need to succeed.


Generator Guru — Keeping more generators running than anyone in the world. When the grid goes down, we keep the lights on.

Why Trust This Guide?

This guide was written by the Generator Guru technical team, qualified engineers with over 18 years of experience supporting 100,000+ customers annually worldwide. We stock over 1,000,000 parts for over 1000 brands across our warehouses in the UK, USA, Canada, EU, Australia, Africa and worldwide. Get free repair support at generatorguru.com/need-help or use our FREE Interactive Repair Guides at gethergoing.com.